Abstract

In this work, WC-17Co, WC-10Co-4Cr, WC-12Co and Cr3C2-25NiCr coatings were deposited on stainless steel using WOKAStar-640 HVOF spraying system. Three WC-based coatings were studied and compared with a chromium carbide-based coating. The microstructure, porosity, micro-hardness, indentation fracture toughness and adhesion strength of the coatings were investigated. The wear test was done by using silica grits as abrasive medium using a load of 20N. The result shows that HVOF sprayed carbide-based coating possesses low porosity, high micro-hardness and high adhesion strength. Three WC-based coatings have higher micro-hardness and indentation fracture toughness compared to the Cr3C2-25NiCr coating. HVOF sprayed carbide coating has good wear resistance under 500°C. The decarburization of WC-based coating has great effect on coating wear resistance. In addition, WC-17Co coating has best wear resistance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.