Abstract

Flat root surface areas of formalin-stored mandibular incisors with plaque and calculus were scaled by sonic (PHATELUS SONIC SCALER, SONIC FLEX 2000, TITAN-S SONIC SCALER) or ultrasonic instruments (HYGIENIST ULTRASONIC SCALER, CAVITRON) or by a new reciprocating scaling insert for the EVA/PROFIN system. The test areas were photographed by SEM and coded micrographs were independently graded by three examiners using the RCI (Remaining Calculus Index) and the RLTSI (Roughness Loss of Tooth Substance Index). The findings revealed that the sonic scalers as a group removed calculus more completely but also left significantly more roughness and loss of tooth substance than the other instruments tested. No difference was seen between the two ultrasonic scalers. The reciprocating insert gave results similar to those of the ultrasonic except for the scaling time which was significantly longer for the new "cleansing principle".

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.