Abstract
The suitability of a strategy for distributing the power generated by a photovoltaic pumping system equipped with two equal pumps working in parallel is proven. This strategy aims to improve energy management and consists of feeding a single pump with all the power generated until it exceeds a threshold value from which the power distribution must be at 50% between the two pumps. This pumping method was compared with the operation mode usually applied in parallel PV pumping facilities (50% of the power always assigned to each pump). A system equipped with two 0.75 kW pumps was employed. The assessment of the facility’s performance under the two alternative working conditions and several pumping heads was conducted using simulation techniques. Both the pumped annual volume and the annual efficiency of the motor-pump group increased when the strategy was applied compared to operation with power distribution at 50%. This increase was greater the higher the head (6.21% at H = 18 m vs. 57.60% at H = 48 m for pumped annual volume and 6.42% at H = 18 m vs. 57.51% at H = 48 m for annual efficiency). The halving of the irradiance threshold and the improved efficiency (36.4% vs. 34.8%) may explain this increase.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.