Abstract

ObjectivesEvaluate the strength degradation of polymeric ligature chains after their immersion in cetylpyridinium chloride-based mouthwashes. Methods240 elastomeric samples from four different manufacturers (Rocky Mountain®, Ormco®, Morelli® and Dentaurum®) in two types of configurations (with and without intermodular links) and divided in 3 groups (distilled water, Vitis CPC Protect® and PERIO·AID® 0.05%) at 5 follow-up periods (0–24 h, 7–14 -21 days) were immersed twice a day for 60 s, following the manufacturers' protocols. A universal traction machine was used to perform the measurements and a post hoc multiple comparisons were based on the Bonferroni test and extended to a 3-way ANOVA test (α = 0.05). ResultsThere was a drop in strength up to 35.9% at 24 h. After a week, the short chains (52%) degraded less than the long ones (57.3%) with significant differences (p < 0.001) and the same pattern was observed until 21 days (p < 0.001). At 24 h, the degradation of the chains exposed in distilled water was 25.8%, in VITIS CPC Protect® 28.6% and in PERIO· AID® 0.05%, 27% with significant differences (p < 0.001). At 21 days, the VITIS CPC Protect® group obtained a much greater loss of strength, being this drop statistically significant (p < 0.001). The chains from Ormco® and RMO® experienced the least loss of force when immersed in the control group or PERIO AID® 0 0.05% (48% and 51%), while Dentaurum's in VITIS CPC Protect® lost more than 75%. ConclusionsThe orthodontic elastomeric chains suffer a sharp drop in strength during the first days of treatment. When comparing the mouthwashes, there were statistically significant differences in terms of strength degradation. Clinical significanceBased on the results, some types of chains, such as the ones without intermodular links from Ormco® showed better properties throughout the study. When immersed in PERIO·AID®0.05%, all showed significantly better results over time. Thus, PERIO·AID®0.05% can be recommended as a complementary oral hygiene element in dental treatments when elastomeric chains are used.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call