Abstract

This study set out to compare the damage done to dentin by three distinct titanium file brands - the Hyflex EDM, the ProTaper Next, and the Waveone Gold Nickel - in order to draw conclusions about which one is the most effective. Forty-first premolars in the mandible with straight canals and single roots were instrumented using Hyflex EDM, Waveone Gold, and Protaper Next. Dentinal flaws after endodontic treatment were studied by sectioning specimens using a hard tissue microtome and analyzing them under a stereomicroscope. There was no discernible variation between the groups in the coronal third (p=0.312) or apical third (p=0.076). Hyflex EDM and Protaper Next differed significantly in the middle portion of the tape (p=0.016). The Hyflex EDM sample had the fewest cracks. There was no statistically significant difference between Hyflex EDM and Waveone Gold; however, Hyflex EDM had fewer fractures in the middle third of the sample than Waveone Gold did. Electric discharge machining (EDM) files made from Hyflex proved to be far superior to their Protaper Next and Waveone Gold counterparts as they induced the fewest cracks in the middle third of the root dentin.