Abstract

Background:Objective in root canal preparation is to develop a shape that tapers from apical to coronal, maintaining the original canal shape. With advent of instruments manufactured from nickel-titanium (NiTi) alloys, there was a significant improvement of quality of root canal shaping, with predictable results and less iatrogenic damage.Aim:The aim of the study was to evaluate the canal centric ability and apical transportation in apical region of newer NiTi file system in root canal using cone-beam computed tomography (CBCT) on extracted molars.Materials and Methods:Root canal of thirty extracted human permanent teeth with mature root apices with 20°–40° of curvature were collected and divided into three groups after initial bio-mechanical preparation: Group 1: canal prepared using ProTaperNext (PTN) file system; Group 2: canal prepared using Mani silk system; and Group 3: canal prepared using V-taper file system. All samples were scanned before and after biomechanical preparation using CBCT. The data collected were evaluated using the Kruskal–Wallis analysis of variance test and Mann–Whitney U-test.Results:It was observed that in apical region Group I (PTN) showed significantly lower mean apical transportation and canal centric ability as compared to Group II (Mani Silk) and Group III (V-taper).Conclusion:It was concluded that PTN rotary system has no canal transportation and maintained centric ability in comparison to Mani and V-taper rotary file system in apical region of curved root canal.