Abstract
Purpose:Intensity modulated radiotherapy (IMRT) plan quality, beam on time and integral dose were compared using 6MV FB (Flattened Beam) and FFFB (Flattening filter free beam) for carcinoma of cervix.Materials and Methods:Ten patients with stage II–IIIB cervix cancer (Ca.Cx) were retrospectively identified from the department database. Target volume (TV) and organ at risk (OAR) were delineated as per Radiation Therapy Oncology Group (RTOG) cancer guidelines. Dose prescribed to planning target volume (PTV) was 50.4Gy in 28 fractions. Two plans (6MV FB IMRT and 6MV FFFB IMRT) were generated to achieve 95% of prescription dose to PTV and sparing OAR as per normal tissue guidelines. Numbers of beams and their orientations were the same for all plans. The homogeneity index (HI), conformity index (CI), treatment monitor unit (MU), beam on time (BOT) and non-tumor integral dose (NTID) were chosen for comparison.Results:FFFB generated plans were clinically acceptable. There was a statistically significant difference among the FB IMRT and FFFB IMRT plans with respect to CI, HI, D50%, D2% in PTV coverage, bladder V50Gy, MU, mean NTID and non-tumor low dose volume.Conclusions:6MV flattened and flattening filter free photon beams produce comparable plans by IMRT. FFF beams allow time efficient treatment delivery and may help reduce the risk of secondary malignances in carcinoma cervix cases.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Asian Pacific Journal of Cancer Prevention : APJCP
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.