Abstract

This paper presents a comparative evaluation of two multiple-loops duty-cycle-based control schemes applied to a three-phase three-switch three-level boost-type rectifier. The control laws are both elaborated on the basis of a state-space averaged model of the converter, expressed in the synchronous rotating frame. On the one hand, a control scheme that uses linear regulators is designed by using the small-signal transfer functions of the converter’s model, which was linearised on the neighbourhood of a suitable steady-state operating point. On the other hand, a non-linear control scheme that uses the input-output feedback linearisation approach is also designed in order to satisfy the same requirements as for the linear control system. For comparison purpose, both control schemes are implemented numerically using the Simulink tool of Matlab, and simulation experiments are carried out in order to test and verify the tracking and regulation performance of each control law, as well as their robustness towards load or mains source disturbance. For the same operating conditions, the performance of the two control laws are analysed and compared in terms of line currents total harmonic distortion (THD) and DC voltage regulation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.