Abstract
In this study, nonlinear static pushover analysis was performed to compare the effectiveness of different carbon fibre-reinforced polymers (CFRP) rehabilitation schemes for existing masonry-infilled RC frames. A three-bay five-storey reinforced concrete (RC) frame with masonry infill walls designed according to previous building codes was modelled as a representative of existing low-rise RC frames. The earthquake retrofitting effects of twelve CFRP strengthening schemes were compared in terms of the global pushover curve, maximum load capacity, maximum interstorey drift ratio (IDR), plastification in the frames, and maximum energy dissipation capacity. The results indicate that the improper selection of a retrofitting scheme is likely to result in the change of the soft storey location, which would cause unexpected damage to structures. The CFRP rehabilitation of both columns and infills for the bottom three floors or more leads to a significant increase in maximum load, maximum IDR, maximum energy, and maximum number of plastic hinges in the frames.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.