Abstract

In this paper, we have discussed about the changes in the system parameters due to the presence of the Interphase transformer (IPT). Two or more rectifier systems with displaced ripple voltages can be paralled with the help of IPT. The parallel operation of two three-pulse controlled converters with IPT is simulated and the difference of with and without the IPT is analyzed. An IPT absorbs voltage difference between DC voltages of the two converters at any instant. The independent operation of the two systems is obtained without any circulating current with the help of IPT. Six-pulse output voltage is obtained by parallel operation of two three phase half bridge controlled converters, similarly twelve pulse output is obtained by connecting two three phase full bridge controlled converters. This results in reduced total harmonic distortions with the use of IPT. This has been verified using MATLAB2014 (a).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.