Abstract

Pulsatile flow of blood in narrow tapered arteries with mild overlapping stenosis in the presence of periodic body acceleration is analyzed mathematically, treating it as two-fluid model with the suspension of all the erythrocytes in the core region as non-Newtonian fluid with yield stress and the plasma in the peripheral layer region as Newtonian. The non-Newtonian fluid with yield stress in the core region is assumed as (i) Herschel-Bulkley fluid and (ii) Casson fluid. The expressions for the shear stress, velocity, flow rate, wall shear stress, plug core radius, and longitudinal impedance to flow obtained by Sankar (2010) for two-fluid Herschel-Bulkley model and Sankar and Lee (2011) for two-fluid Casson model are used to compute the data for comparing these fluid models. It is observed that the plug core radius, wall shear stress, and longitudinal impedance to flow are lower for the two-fluid H-B model compared to the corresponding flow quantities of the two-fluid Casson model. It is noted that the plug core radius and longitudinal impedance to flow increases with the increase of the maximum depth of the stenosis. The mean velocity and mean flow rate of two-fluid H-B model are higher than those of the two-fluid Casson model.

Highlights

  • Atherosclerosis is an arterial disease in humans, which leads to the malfunctioning of the cardiovascular system 1

  • The present comparative analysis brings out several useful rheological properties of blood when it flows through narrow tapered arteries with mild overlapping time-dependent stenosis in the presence of external periodic body acceleration, treating it as i two-fluid H-B model and ii two-fluid Casson model

  • I The plug core radius, wall shear stress, and longitudinal impedance to flow are marginally lower for the two-fluid H-B model compared to the corresponding flow quantities of the two-fluid Casson fluid model

Read more

Summary

Introduction

Atherosclerosis is an arterial disease in humans, which leads to the malfunctioning of the cardiovascular system 1. It is appropriate to represent the suspension of all the erythrocytes in the core region of the two-fluid model of blood when it flows in narrow diameter arteries at low shear rates by H-B fluid rather than Casson fluid. The pulsatile flow of two-fluid H-B fluid model and two-fluid Casson fluid model for blood flow through narrow tapered arteries with mild overlapping stenosis under periodic body acceleration has not been studied so far, to the knowledge of the authors. In this study, a comparative study is performed for the pulsatile flow of two-fluid H-B and Casson models for blood flow in narrow tapered arteries with mild overlapping stenoses in the presence of periodic body acceleration. The main results are summarized in the concluding Section 4

Mathematical Formulation
Nondimensionalization Let us introduce the following nondimensional variables:
Perturbation Method of Solution
14 The resistance to flow in the artery is given by
Governing Equations and Boundary Conditions
R1 3 16 R
R1 3 8R
Numerical Simulation of the Results
Plug Core Radius
Plug Flow Velocity
Velocity Distribution
Flow Rate
Wall Shear Stress
Longitudinal Impedance to Flow
Some Possible Clinical Applications
Conclusions