Abstract
A 90° Halbach permanent magnet array coreless axial flux permanent magnet synchronous generator for wind power generation is compared with a conventional axial flux permanent magnet generator with cut cake type permanent magnet. 2D analytic model of generator is established. The air gap magnetic fields of two generators are analyzed by analytical method, and the air gap magnetic density and harmonic content are analyzed. Then the influence of different parameters on voltage total harmonic distortion is analyzed by changing the pole arc coefficient, air gap length, permanent magnet thickness and number of turns. Two prototypes of generators are manufactured, and the correctness of the simulation results is verified by experiments.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Electrical Engineering & Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.