Abstract
The research reported in this paper deals with the potential of detecting non-simultaneous operation in on-load tap-changer (OLTC) using an acoustic emission method. Tests conducted under laboratory conditions were carried out using an OLTC model. Three transducers with different characteristics were used: WD 17 AH, D9241A, and R15α, alongside oscillography as the reference method. The use of two new descriptors in the time domain was proposed. The feasibility of detecting the defect with different piezoelectric transducers was investigated. As a result of the analysis of the results, it was found that each piezoelectric transducer can identify nonsimultaneous operation of the switch. The most significant changes in descriptor values occurred in the time domain, and the most effective transducer turned out to be R15α.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.