Abstract
ObjectiveProGAV and ProGAV2.0 adjustable valves are extensively used for treating hydrocephalus in pediatric patients. This study aims to conduct a comprehensive comparison between these two valves concerning their survival and complication rates.MethodsThis retrospective study included all pediatric patients who underwent ProGAV or ProGAV2.0 valve implantation at our neurosurgical clinic from August 2008 to August 2020. A comparative analysis was performed considering age, gender, follow-up duration, complication and survival rates, adjustments, spontaneous adjustments, and adjustment difficulty rates. All valves were followed up for a maximum of 3 years.ResultsInclusion involved 333 cases (mean age of 5.4 ± 5.1 years; 54.1% males), comprising 173 cases (52.0%) with ProGAV valve implantation and 160 cases (48.0%) with ProGAV 2.0. Early complications within the first month post-implantation were observed in 51 cases (15.3%). No significant differences were noted in valve implantation indications, age distribution, or survival duration (27.1 vs. 27.8 months, p = 0.629) between the two groups. Predominant indications for implantation were post-hemorrhagic hydrocephalus and aqueduct stenosis for both valve types. Notably, both valves showed non-significantly different explantation rates during the first three years after implantation (34.7% vs. 29.7%, p < 0.289). However, there was a significantly higher early post-implantation complication rate (22% vs. 9.4%, p = 0.002), and a significantly increased association with difficulties in valve adjustments and spontaneous adjustments (p = 0.041 and 0.011, respectively). ProGAV2.0 cases displayed notably enhanced clinical and radiological improvement within the initial 6 months after implantation (p = 0.001 and p = 0.038). Younger children (< 2 years of age) also experienced significantly more valve adjustment difficulties (p = 0.049) and had higher rates of valve explantation (p < 0.001).ConclusionThe findings of this study highlight the superior performance of the ProGAV2.0 valve in terms of complication rate and maladjustment rate when employed in the treatment of pediatric hydrocephalus. Both valves demonstrated an acceptable survival rate with 65.3% for ProGAV and 71.3% for ProGAV2.0 within three years of implantation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.