Abstract

The increase in alcohol consumption in society has not only led to a number of medical issues but has also become a matter of considerable legal importance. Thus, there is both scientific interest and the necessity to diagnose alcohol abuse in the application of the provisions of the law through laboratory tests that ensure maximum objectivity. The purpose of this work is to study and compare the diagnostic performance of two of the main markers of alcohol abuse, serum carbohydrate-deficient transferrin (CDT) and Ethyl glucuronide (EtG) in a group of 336 driving under the influence (DUI) of alcohol offenders. Thus, it is possible to establish the best marker of alcohol consumption in order to assess the fitness to drive of DUI subjects.EtG was detected in 55 hair samples, while CDT was detected in 5 blood samples. Of the EtG-positive subjects 96,4% had CDT values below the cut-off. While CDT refers to an alcohol consumption of approximately the previous 10 days, EtG allows to detect an excessive alcohol consumption of the last few months. Because of these two different time-windows, EtG proves to be more reliable, since it is more difficult for subjects to change their drinking practice to test negative to toxicological analysis. The determination of Ethyl glucuronide on hair matrix is a valuable tool for the diagnosis of alcohol abuse, with high sensitivity and specificity and certainly greater reliability than traditional markers such as CDT, being a direct marker of alcohol consumption.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call