Abstract

The performance of three time of wetness (TOW) determination methods during outdoor exposure was examined. Two impedance-based TOW sensor types, RH, and temperature sensors were exposed to coastal marine and laboratory environments for up to three months. The sensor and ISO 9223 methods examined provided incomparable estimates. Inaccuracy of the ISO method originated from a humidity threshold well above the drying point of deposited aerosols and differences between surface and ambient RH. TOW sensor accuracy was linked to electrode configuration. Small electrode spacing was demonstrated to be required to capture the range of wetting events of importance to atmospheric corrosion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.