Abstract
A compact in-line interferometer is proposed and experimentally demonstrated for gas refractive index (GRI) measurement. The sensor comprises a tapered four-core fiber (TFCF) sandwiched between two single-mode fibers (SMFs), forming an in-line SMF-TFCF-SMF structure. The fiber taper acts as a bridge between the external GRI variation and the multimode interference within the TFCF segment. A high sensitivity of 1280.94dB/refractive index unit is obtained in GRI measurement around 1.0. Temperature change only shifts the interference wavelength, and the cross-sensitivity of temperature can be ignored by intensity demodulation. The proposed gas refractometer, with its improved performance, can be a good candidate for chemical sensing or bio-sensing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.