Abstract

In situ chemical monitoring at deep-sea hydrothermal vents remains a challenge. Particularly, tools are still scarce for assessing the ranges and temporal variability of sulfide in these harsh environmental conditions. There is a particular need for compact and relatively simple devices to enlarge the capacity of in situ measurements of this major energy source in chemosynthetic ecosystems. With this objective, a voltammetric sensor based on a bare-silver working electrode was developed and tested in real conditions. In the laboratory, the sensor presented a linear response from 10 to 1000μM sulfide, together with a low pH sensitivity and moderate temperature dependence. The device was operated at 850 and 2500m depth during 3 cruises over two different vent fields. The autonomous potentiostat (290mm length, ∅ 35mm) equipped with laboratory-made electrodes was mounted on a wand, for manipulation from a submersible, or on a holder for unattended deployments. The system was applied in mussel, tubeworm and annelid worm habitats, characterized by different ranges of sulfide concentration, pH and temperature. Calibrations performed before and after each deployment confirmed the stability of the sensor response over a few hours to 11 days, with a maximum drift of 11.4% during this period. Short-term measurements in the vicinity of Riftia pachyptila and Alvinella pompejana were consistent with previous results on these habitats, with concentrations ranging from 20 to 140μM and 100 to 450μM and sulfide versus temperature ratio of 14μM°C−1 and 20μM°C−1, respectively. A continuous 4-day record on a bed of Bathymodiolus Thermophilus mussels furthermore illustrated the capacity of the sensor to capture fluctuating sulfide concentration between 0 and 70μM, in combination to temperature, and to investigate the changes in the sulfide versus temperature ratio over time. The method has a higher detection limit (<10μM) than previous in situ sulfide measurement methods, but has the advantage of selectivity to free sulfide (compared to colorimetry), low pH sensitivity (compared to amperometry) and lower reconditioning requirement for electrode surface (with respect to gold-amalgam voltammetry). This sensor is therefore a valuable complementary tool for discrete and continuous measurements within the moderate temperature environment of fauna at deep-sea vents.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.