Abstract

To report the development of easy-to-use magnetic resonance imaging (MRI) fractal tools deployed on platforms accessible to all. The trabeculae of the left ventricle vary in health and disease but their measurement is difficult. Fractal analysis of cardiac MR images can measure trabecular complexity as a fractal dimension (FD). This Health Insurance Portability and Accountability Act (HIPAA)-compliant study was approved by the local Institutional Review Board. Participants provided written informed consent. The original MatLab implementation (region-based level set segmentation and box-counting algorithm) was recoded for two platforms (OsiriX and a clinical MR reporting platform [cvi42 , Circle Cardiovascular Imaging, Calgary, Canada]). For validation, 100 subjects were scanned at 1.5T and 20 imaged twice for interstudy reproducibility. Cines were analyzed by the three tools and FD variability determined. Manual trabecular delineation by an expert reader (R1) provided ground truth contours for validation of segmentation accuracy by point-to-curve (P2C) distance estimates. Manual delineation was repeated by R1 and a second reader (R2) on 15 cases for intra/interobserver variability. FD by OsiriX and the clinical MR reporting platform showed high correlation with MatLab values (correlation coefficients: 0.96 [95% CI: 0.95-0.97] and 0.96 [0.95-0.96]) and high interstudy and intraplatform reproducibility. Semiautomated contours in OsiriX and the clinical MR reporting platform were highly correlated with ground truth contours evidenced by low P2C errors: 0.882 ± 0.76 mm and 0.709 ± 0.617 mm. Validity of ground truth contours was inferred from low P2C errors between readers (R1-R1: 0.798 ± 0.718 mm; R1-R2: 0.804 ± 0.649 mm). This set of accessible fractal tools that measure trabeculation in the heart have been validated and released to the cardiac MR community (http://j.mp/29xOw3B) to encourage novel clinical applications of fractals in the cardiac imaging domain. 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1082-1088.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.