Abstract
Aiming at the disunity problems of the interface types and protocols existing in the communication between the touch screen and the DSP controller, this paper puts forward a kind of communication method based on MODBUS protocol of the Mitsubishi touch screen and DSP controller. By using a standard RS232 interface and MODBUS RTU data transmission format realize the asynchronous communication between GOT touch screen and TMS320F2812 controller. Through the RS485 bus, DSP achieves the communication with ABB frequency converters. Using this method Mitsubishi touch screen, DSP and frequency converter finished communication. So that touch screen can display the working status of the ABB frequency converters in real time. It has been verified by test that data transmission is reliable and good real-time.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.