Asymmetrical and symmetrical dual three-phase (six-phase) adjustable speed drives with control algorithms, providing elimination of undesirable common-mode voltages, have been analyzed in the paper. In particular, asymmetrical six-phase motor drive with common-mode voltage cancellation is based on dual neutral-point-clamped inverters with specialized algorithms of synchronized pulsewidth modulation (PWM). Symmetrical dual three-phase system with common-mode voltage elimination is based on two standard three-phase inverters, with the 600-phase-shift of signals of the two inverters. Basic schemes of synchronized PWM, applied for control of both two-level and three-level inverters, have been analyzed and compared. Simulations give a behavior of dual three-phase systems with algorithms of synchronized PWM, providing elimination of undesirable common-mode voltages.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.