Abstract

Common Mode Voltage (CMV) in variable speed drives is a source of electromagnetic interference and bearing currents. These issues are exacerbated in underground mining applications due to the specific earthing and protection requirements. This paper compares two inverter options for an industrial AC drive: a three-leg inverter and a four-leg inverter, with the view of CMV mitigation. The CMV mitigation strategy is based on Model Predictive Control (MPC). To reduce the computational burden associated with MPC, a computationally efficient modified model predictive control (MMPC) strategy is presented. The findings of the paper are validated by extensive simulations in the Matlab-Simulink©software environment. The presented results show a significant reduction of CMV in three-leg inverter and a complete CMV elimination in four-leg inverter. Experimental validation of the results presented in the paper is underway.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.