Abstract
In this paper, an in-fiber Mach–Zehnder interferometer (MZI) is developed for refractive index (RI) sensing through core-offset splicing. In MZI, two ends of a section erbium-doped fiber are asymmetrically spliced with two pieces of single-mode fiber in order to get large contrast ratio of fringes. The comprehensive experimental measurements are then performed in terms of temperature and ambient RI. Owing to high sensitive consistency in temperature, a novel common difference compensation (CDC) method is introduced to achieve the self-elimination of cross-sensitivity. Thus the measurement error (∼1.2%) can be deleted by CDC and the corrected sensitivity (-74.22nm/RIU) is obtained without the crosstalk from temperature In addition, high working stabilities are demonstrated in the fabricated RI sensor in terms of wavelength (±0.02 nm) and intensity (±0.03 dB).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.