Collective Thomson Scattering (CTS) diagnostics measure the scattering spectrum of monochromatic incident radiation off collective fluctuations in the plasma. In this contribution, we present the first results from the upgraded CTS diagnostic at Wendelstein 7-X (W7-X) operating in the frequency range between 172 and 176 GHz. This frequency range allows for minimization of noise originating from the electron cyclotron emission in the plasma. Consequently, the good signal-to-noise ratio allows measurements of fast ions or bulk plasma parameters with higher temporal resolution compared with the previously used 140 GHz system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.