Abstract

To present and discuss beam characteristics and commissioning process of the first gantry-mounted accelerator single room pencil beam scanning (PBS) proton system. The Mevion HYPERSCAN employs a design configuration with a synchrocyclotron mounted on the gantry to eliminate the traditional beamline and a nozzle that contains the dosimetry monitoring chambers, the energy modulator (Energy Selector (ES)), and an Adaptive Aperture (AA). To characterize the beam, we measured the integrated depth dose (IDDs) for 12 energies, from highest energy of 227MeV down to 28MeV with a range difference~2cm between the adjacent energies, using a large radius Bragg peak chamber; single-spot profiles in air at five locations along the beam central axis using radiochromic EBT3 film and cross compared with a scintillation detector; and determined the output using a densely packed spot map. To access the performance of AA, we measured interleaf leakage and the penumbra reduction effect. Monte Carlo simulation using TOPAS was performed to study spot size variation along the beam path, beam divergence, and energy spectrum. This proton system is calibrated to deliver 1Gy dose at 5cm depth in water using the highest beam energy by delivering 1 MU/spot to a 10×10 cm2 map with a 2.5mm spot spacing. The spot size in air varies from 4mm to 26mm from 227MeV to 28MeV at the isocenter planewith the nozzle retracted 23.6 cm from isocenter. The beam divergence of 28MeV beam is~52.7 mrad, which is nearly 22 times that of 227MeV proton beam. The binary design of the ES has resulted in shifts of the effective SSD toward the isocenter as the energy is modulated lower. The peaks of IDD curves have a constant 80%-80% width of 8.4mm at all energies. The interleaf leakage of the AA is less than 1.5% at the highest energy; and the AA can reduce the penumbra by 2mm to 13mm for the 227 and 28MeV energies at isocenter plane in air. The unique design of the HYPERSCAN proton system has yielded beam characteristics significantly different from that of other proton systems in terms of the Bragg peak shapes, spot sizes, and the penumbra sharpening effect of the AA. The combination of the ES and AA has made PBS implementation possible without using beam transport line and range shifter devices. Different considerations may be required in treatment planning optimization to account for different design and beam characteristics.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call