Abstract

For original paper see H. Deng, ibid., vol.11, no.2, p.179-182, (2004). This comment points out some errors in the correlation calculations and conclusions in the literature. The ambiguity function and cross-ambiguity function for discrete frequency-coding waveform (DFCW) with arbitrary firing order are analyzed in that letter to corroborate the judgement. It shows that range autocorrelation sidelobe peak (ASP) for DFCW fluctuates around 0.21, the Doppler tolerance has sinc function form, while the range cross-correlation peak (CP) between two DFCWs is heavily varied with the different firing order. The correlation values are recalculated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.