Abstract

The FEMA P-807 guideline titled Seismic Evaluation and Retrofit of Multi-Unit Wood-Frame Buildings with Weak First Stories is a new approach for building retrofit. It goes beyond current building codes and standards by quantifying performance in probabilistic terms. The authors performed an independent review of P-807, and the resulting commentary herein covers five topics: (1) building lateral force-drift (backbone) curves, (2) building interstory drift limits, (3) lateral strength requirements, (4) collapse safety margins, and (5) site class effects. It was concluded that P-807 may be an efficient way for relative ranking and selection of retrofit designs—but it has questionable accuracy for predicting actual building performance (i.e., the probability that a particular seismic intensity will result in a meaningful state of damage for a specific building).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.