Abstract

In their article, ‘‘AC frequency characteristics of coplanar impedance sensors as design parameters’’, Hong et al.1 present an analytical model for the calculation of the resistance between two electrodes in a microchannel. However, their measurements fit poorly with their suggested model, and they attribute the discrepancies to electrode thickness and a ‘fringing effect’. In this note we show that the discrepancies are due to the neglected channel height in their model, and that by including two additional transforma ions, the resistance between two

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.