Abstract

A field-oriented control strategy for induction machines which does not use mechanical sensors is presented. The rotor flux is observed by a reduced-order Luenberger-type observer based on a model using a stator-fixed reference frame. An estimate of the rotation speed is derived from the flux vector, the measured stator currents and the field orientation angle. Simulations demonstrate that this control strategy performs well even in the presence of parameter variations up to ±50% (resistances)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.