Abstract

This paper presents the results of the combustion system test of the MS7001F installed at the Virginia Power Chesterfield station. Tests of water and steam injection for NOx control were performed. Results of emissions, combustor dynamics, and combustor hardware performance are presented. Emissions test results include NOx, CO, unburned hydrocarbons, VOC, and formaldehyde levels. Combustor dynamic activity over a range of diluent injection ratios, and the performance of an actively cooled transition duct are also discussed. Combustion system mechanical performance is described following the first combustion system inspection.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.