Abstract

Flue gas emissions and particle size distribution were investigated during combustion experiments of wood, forest residue and mixtures of these two. The combustion experiments were carried out in a grate fired multi-fuel reactor with and without air staging at stable operation conditions and constant temperature of 850 °C. The overall excess air ratio was held at 1.6, and the primary excess air ratio was 0.8 during air staged experiments. NOx emissions are reduced by air staging. Fly ash particle concentration of forest residues in the flue gas is lower than wood. Aerosols number increased in the staged experiments for fuel blends.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.