Abstract

Increasing the absorber plate surface in a solar air heater system (SAHs) can increase thermal efficiency, heat transfer coefficient, and Nusselt number. This paper includes the development of a 3-dimensional computational fluid dynamics (3-D CFD) model for predicting the location of the absorber plate from the bottom of the collector, followed by its validation using experimental data. Various geometrical types are investigated to determine optimal design features, such as Type I, Type II, Type III, Type IV, and Type V. A comprehensive analysis is performed to achieve this goal, including thermal efficiency, heat transfer coefficient, and Nusselt number analyses. Results indicate that Type V has better performance than other geometries. When the absorber plate location Type V with a distance (dis) of 0.012 m far from the bottom of the collector. As a result, increases in the average thermal efficiency, heat transfer coefficient, and Nusselt number of the system are 19 %, 53%, and 268.8%. Compared to Type I, when the absorber plate was lying on the collectors without a gap between the absorber and collector bottom.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.