An unobtrusive bed integrated system for monitoring physiological parameters during sleep is presented and evaluated. The system uses textile electrodes attached to a bed sheet for measuring multiple channels of electrocardiogram. The channels are also combined in order to form several additional ECG leads. One lead at a time is selected for beat-to-beat-interval detection. The system also includes force sensors located under a bed post for detecting respiration and movements. The movement information is also used to assist in heart rate detection and combining the ECG derived respiration information with respiration information derived from force sensors, is investigated. The authors tested the system with ten subjects in one hour recordings and achieved an average of 95.9% detection coverage and 99 percentile absolute error of 3.47 ms for the BB-interval signal. The relative mean absolute error of the detected respiration cycle lengths was 2.1%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.