Abstract

We sought to determine whether the combination of low-intermediate clinical risk of acute lower extremity deep vein thrombosis (DVT) and negative ELISA D-dimer assay can eliminate the need for duplex ultrasonography. Three hundred thirty-six patients prospectively underwent clinical risk stratification (low, intermediate, and high), D-dimer testing, and duplex ultrasonography. Thirteen of 145 intermediate-risk patients had acute DVT; 11 (85%) had a positive D-dimer. Two of 118 low-risk patients had acute DVT; both had a positive D-dimer. Intermediate-high risk stratification alone had sensitivity of 93.9% (95% CI: 80.3–98.3%) and a NPV of 98.3% (95% CI: 94.0–99.5%) for acute DVT. For all patients, a positive D-dimer alone had a sensitivity of 93.9% (95% CI: 80.3–98.3%) and a NPV of 98.6% (95% CI: 95.1–99.6%). The combination of D-dimer and intermediate-high risk classification had a sensitivity of 100% (95% CI: 89.4–100%) and a NPV of 100% (95% CI: 98.9–100%). In suspected acute lower extremity DVT, the combination of intermediate-high clinical risk and positive D-dimer has a high sensitivity and NPV, possibly eliminating the need for duplex ultrasound in this group of patients.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.