In this paper, we describe a new approach to the continuous operation of a transverse spin-exchange optically pumped NMR gyroscope that utilizes modulation of both the applied bias field and the optical pumping. We demonstrate the simultaneous, continuous excitation of 131Xe and 129Xe using this hybrid modulation approach and the real-time demodulation of the Xe precession using a custom least-squares fitting algorithm. We present rotation rate measurements with this device, with a common field suppression factor of ∼1400, an angle random walk of 21 μHz/Hz, and a bias instability of ∼480 nHz after ∼1000 s.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.