Abstract

Background: This study compared outcomes of combined toric versus spherical intraocular lens (IOL) implantation in patients with low corneal astigmatism.
 Methods: In this retrospective contralateral study, patients with corneal astigmatism who received combined toric (FIL 611 T, Soleko, Rome, Italy) and spherical IOL (FIL 611 T, Soleko, Rome, Italy) implants were recruited. Eyes were examined preoperatively and then again 3 months postoperatively. Postoperatively, uncorrected distance visual acuity (UCDVA), residual astigmatism, and spherical equivalent (SE) were compared between the toric IOL-implanted eyes and the spherical IOL-implanted fellow eyes.
 Results: Among the 46 included cases (age 69 ± 12.7 years [mean± standard deviation]; range: 60‒78 years), 86.9% of eyes (n = 40) in the toric IOL group had a postoperative refractive cylinder of ≤ 0.25 diopters (D), compared with 4.3% (n = 2) of eyes in the spherical IOL group. Both groups showed a statistically significant reduction in refractive cylinder and improvement in UCDVA after cataract surgery (both P = 0.01). Similarly, toric IOLs were superior (69.6%) to spherical lenses (2.2%) in obtaining a SE of ≤ 0.25 D.
 Conclusions: To our knowledge, no previous study had sought to compare low-power toric and spherical IOLs in low corneal astigmatism in the same patient's eyes. Our findings suggest that low-power toric IOLs may result in good refractive outcomes as compared with spherical IOLs implanted in the fellow eye of the same patient, although both result in significant UCDVA improvement. Well‐designed clinical research studies with a longer follow-up and more participants are necessary to confirm these findings.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call