Abstract
In this report, two collinear laser pulses were used to investigate the laser-induced breakdown spectroscopy (LIBS) emission from aluminum (Al) plasma, for the two cases with and without magnetic field. Time-integrated emission spectra for atomic lines with combined techniques of dual-pulse LIBS (DP-LIBS) and magnetic field were measured to be higher than those recorded with DP-LIBS only. The enhancement factors of about 11 and 5 were obtained in DP-LIBS with and without magnetic field, respectively. The effect of inter-pulse delay time on the intensity enhancement shows a maximum enhancement factor of about 70 and 40 in DP-LIBS with and without magnetic field for atomic line (308.2nm). It was obvious that the combined enhancement effects of dual-pulse and magnetic field in LIBS was stronger than that of DP-LIBS only.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.