Abstract

An attempt has been made to explore the combined effect of structured surfaces (segmented finned surface and uniform cross-section surface) and Rhamnolipid biosurfactant to improve heat transfer rate in pool boiling. Experimental investigations were performed at normal atmospheric condition and till reaching critical heat flux. The results shows that the segmented finned surface has shown better heat transfer than plain surfaces, with a 200% increase in heat transfer coefficient. In contrast, a uniform cross-section surface showed an improvement in heat transfer coefficient of 107% over a plain surface. The reasons for better thermal performance in segmented finned configuration can be associated to the reduced surface tension of the working fluid increasing more nucleation sites. Additionally, better rewetting phenomena and bubble evolution from the segmented finned surface have also assisted in improving the heat transfer rate. Moreover, the pool boiling results of all the heating surfaces with surfactant solution is compared with pure water. It has been observed that all heating surfaces have performed better with surfactant solution compared to pure water. However, the CHF obtained on all heating surfaces with surfactant solution were lesser than pure water. Low CHF is due to the foamability of the surfactant solution.