Abstract

The present study investigates the combined influence of Channel to Rib Width (CRW) ratio and clamping pressure on the structure and performance of High Temperature-Polymer Electrolyte Membrane Fuel Cell (HT-PEMFC) using a three-dimensional numerical model developed previously. It also considers the impact of interfacial contact resistance between the Gas Diffusion Layer (GDL) and Bipolar Plate (BPP). The structural analysis of the single straight channel HT-PEMFC geometry shows that the von-Mises stress greatly increases in the GDL under the ribs as the CRW ratio increases resulting in considerably high deformation. The cell performance analysis depicts the significance of ohmic resistance and concentration polarization for different CRW ratios, particularly at higher operating current densities. However, in low to medium current density regions, the CRW ratio has little influence on cell performance. A substantial impact on the species, overpotential, and current distributions is observed. The findings also reveal that the CRW ratio significantly affects the temperature distribution in the cell.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.