Abstract

AbstractThis study is concerned with the strength limit state of serial bolted connections in structural steel plates. It points out that the ultimate load capacity of a serial bolted connection failing in combined bearing and shear-out cannot be computed as the simple sum of the respective ultimate bearing and ultimate shear-out capacities, which is implicitly permitted in design specifications worldwide. Based on the laboratory test results of 10 hot-rolled steel plate specimens composed of three different grades with nominal thicknesses ranging from 5 to 8 mm, the paper first establishes the ultimate bearing coefficient of a 20-mm bolted connection in a structural steel plate to be 3.5. Coupled with the shear-out equation previously derived, a design equation where the shear-out capacity of the downstream bolt varying quadratically with the end distance is then proposed to determine the combined bearing and shear-out capacity. The proposed equation is demonstrated through verification against independe...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.