Abstract

Static stiffness of fixed column jib crane directly affected operating and safety performance. Using ANSYS software for finite element analysis with the consideration of the combined effects of spiral arm and column and the whole structure, the integrated finite element analysis model was established for the whole jib crane and arm-side deflection formula for this type of crane structure was derived. Results verified the deflection formula and the reasonable camber design for spiral arm. Based on the verification, it is aimed to enhance the degree of static stiffness of crane, to improve its response to static stiffness of bend arm to set appropriate degree. In particular, arm deflection ensures correct calculation of static stiffness of the crane foundation, but also on the right arm to set an important basis for degree bend.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.