Abstract

Ochratoxin A (OTA) detection is critical for public health safety. This study proposes a G-quadruplex-Hemin/iodide (G4-Hemin/I−)-mediated non-enzyme redox cycling amplification (RCA) system for dual-modal (colorimetric and photothermal thermometer) OTA analysis. The proposed aptasensor platform for point-of-care testing employs a common thermometer for quantitative signal readouts. The OTA aptamer folds into a G4 structure, which significantly enhances the catalytic activity in the presence of I− after RCA reaction. Moreover, a notable temperature enhancement causes color changes, providing an ultrasensitive and label-free platform for OTA detection. Further, the designed sensor was applied to OTA content determination in corn samples and achieved satisfactory results compared to a commercial enzyme-linked immunoassay kit. The proposed dual-mode aptasensor is simple, highly sensitive (1 pg/mL for colorimetric method, 0.8 pg/mL for photothermal method), selective, and suitable for low-cost instrument-free bioanalysis in low-resource settings.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.