Abstract

To compare the accuracy of the equivalent keratometry reading (EKR) from a color LED corneal topographer (Cassini) with that of other no-history formulas for intraocular lens (IOL) power calculation in eyes with previous myopic excimer laser surgery. Centro de Oftalmología Barraquer, Barcelona, Spain. Retrospective case series. The refractive outcomes of the Cassini EKR entered into the Haigis formula were compared with those of the Barrett True-K, Haigis-L, and Shammas-PL formulas and the Triple-S method combined with the Haigis formula. Optimized lens constants for virgin eyes were used. The mean prediction error (PE), the median absolute error (MedAE), and the percentage of eyes with a PE within ±0.25 diopter (D), ±0.50 D, ±0.75 D, and ±1.00 D were calculated. The study comprised 37 patients (37 eyes). The Haigis-L, Shammas-PL, and Barrett True-K no-history methods produced a myopic mean PE that was significantly different from zero (P < .001, P < .001 and P = .004, respectively), whereas the mean PEs of Cassini EKR and the Triple-S combined with the Haigis formula were not different from zero (P > .05). Repeated-measures analysis of variance disclosed a significant difference among the PE of all methods (P < .0001). The MedAE of the Cassini EKR, Barrett True-K, Haigis-L, Shammas-PL, and Triple-S was, respectively, 0.34 D, 0.34 D, 0.49 D, 0.48 D, and 0.31 D (P = .0026). The performance of the combination of standard Haigis formula with Cassini EKR was comparable to other no-history formulas in eyes with previous myopic excimer laser surgery.