Abstract

Simple SummaryThe quality and completeness of colonoscopies might be hampered by suboptimal visualization; often leading to a CT colonography. Colon capsule endoscopy has been suggested as an alternative to CT colonography following incomplete colonoscopy. Colon capsule endoscopy is conducted by the ingestion of a video capsule, which then transmits pictures, allowing complete visualization of the colon and rectum. In our study, we compared the completion rates and diagnostic yields (detection of polyps) of colon capsule endoscopy with those of CT colonography by conducting a systematic review with meta-analysis. We found that the completion rate of CT colonography was slightly higher than that of colon capsule endoscopy, while the diagnostic yield of colon capsule endoscopy was higher, especially when comparing findings of any size polyps. This knowledge might aid clinicians when planning further diagnostics following incomplete colonoscopies.Following incomplete colonoscopy (IC) patients often undergo computed tomography colonography (CTC), but colon capsule endoscopy (CCE) may be an alternative. We compared the completion rate, sensitivity and diagnostic yield for polyp detection from CCE and CTC following IC. A systematic literature search resulted in twenty-six studies. Extracted data included inter alia, complete/incomplete investigations and polyp findings. Pooled estimates of completion rates of CCE and CTC and complete colonic view rates (CCE reaching the most proximal point of IC) of CCE were calculated. Per patient diagnostic yields of CCE and CTC were calculated stratified by polyp sizes. CCE completion rate and complete colonic view rate were 76% (CI 95% 68–84%) and 90% (CI 95% 83–95%). CTC completion rate was 98% (CI 95% 96–100%). Diagnostic yields of CTC and CCE were 10% (CI 95% 7–15%) and 37% (CI 95% 30–43%) for any size, 13% (CI 95% 9–18%) and 21% (CI 95% 12–32%) for >5-mm and 4% (CI 95% 2–7%) and 9% (CI 95% 3–17%) for >9-mm polyps. No study performed a reference standard follow-up after CCE/CTC in individuals without findings, rendering sensitivity calculations unfeasible. The increased diagnostic yield of CCE could outweigh its slightly lower complete colonic view rate compared to the superior CTC completion rate. Hence, CCE following IC appears feasible for an introduction to clinical practice. Therefore, randomized studies investigating CCE and/or CTC following incomplete colonoscopy with a golden standard reference for the entire population enabling estimates for sensitivity and specificity are needed.

Highlights

  • During incomplete colonoscopy (IC), the scope rarely reaches the ascending colon (4–25%), and colonoscopy is often terminated in the sigmoid colon (22–43%) [1,2,3,4] or the rectum (6–10%) [3,5], necessitating further evaluation of the colon

  • colon capsule endoscopy (CCE) following IC appears feasible for an introduction to clinical practice

  • If CCE is better for detecting small lesions compared to computed tomography colonography (CTC), it may still be inhibited by a completion rate that is dependent on the battery lifetime exceeding the total transit time of the capsule

Read more

Summary

Introduction

During incomplete colonoscopy (IC), the scope rarely reaches the ascending colon (4–25%), and colonoscopy is often terminated in the sigmoid colon (22–43%) [1,2,3,4] or the rectum (6–10%) [3,5], necessitating further evaluation of the colon. This is performed by repeat colonoscopy or computed tomography colonography (CTC).

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call