Abstract

In excised dog lungs, collateral resistance was measured among separate groups of alveoli. Alveoli beneath the pleural surface were multipunctured by a small needle, and alveolar pressure and flow were measured in capsules glued onto the punctured pleural surface. When the airway opening was closed, collateral ventilation appeared to occur mainly through the regular airway system, but not through the collateral channels. When the airway opening and the segmental bronchus were occluded, collateral airflow appeared to occur first, within the segment through its airway system; second, through the intersegmental collateral channels to other segments; and third, to output alveoli through the airway system. When the airway was obstructed down to the bronchilar level with silicone rubber, collateral resistance became extremely high. It was concluded that collateral resistantce at the alveolar level was considerably higher than the resistance in the regular airway system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.