ABSTRACT TO help establish satisfactory design criteria and operating procedures for the natural ventilation of warm swine buildings, data was taken in one totally slotted floor building for sow gestation and one similar building for swine finishing. Many other naturally ventilated swine buildings were visited to determine what combination of ventilation openings and management practices give satisfactory results. Inlet and outlet sizes can be calculated by the formula Q = EAV, with E (effectiveness factor) assumed to be 0.35 and V (wind velocity) assumed to be 12 km/h (7.5 mph). Calculated opening sizes will be satisfactory over a wide range of outside temperatures and wind velocities because swine weighing over 34 kg (75 lb) will perform adequately in a range of inside temperatures from about 7 to 21 C. Provisions must be made for reducing opening sizes temporarily during severe winter storms.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.