Abstract
The purpose of this study was to assess differences in observed pain-related behaviors during cannulation between a device combining cold and vibration (Buzzy) and the standard care (EMLA patch). Patients 18 months to 6 years old, requiring venous access in a pediatric emergency department, received either the Buzzy device or the EMLA patch. Predefined week randomization ensured equal allocation to the 2 intervention groups. Pain during cannulation was measured using the Children's Hospital of Eastern Ontario Pain Scale. Parent and nurse reports, cannulation success, and venous access times were also assessed. In total, 607 included patients were randomized into the Buzzy group (n = 302) or the EMLA group (n = 305). Observed pain-related behaviors scores, parent-assessed pain scores, and nurse-reported pain ratings were higher with Buzzy. Pain relief by a combination of cold and vibration during cannulation is not as effective as the standard-care method in children 18 months to 6 years old.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.