Abstract

To quantify differences in waste and cost of disposable equipment between different tonsillectomy techniques. Prospective study of waste attributable to disposable waste produced by tonsillectomy surgery. Disposable equipment required for tonsillectomy using cold, monopolar electrocautery (ME), and coblation techniques was measured; and differences in mass, volume, and cost of equipment between the 3 techniques were quantified. Cold technique was found to produce the least waste and have the lowest cost attributable to disposable surgical equipment. Projected single-case savings in mass and volume of waste resulting from using cold technique compared to ME were 1.272 kg and 1.013 L, respectively, and 1.043 kg and 1.723 L compared to coblation. Projected single-case savings in cost of disposable equipment for cold technique compared to ME were US$9.35 and US$185.05 compared to coblation. Using cold technique for adult tonsillectomy reduces waste and cost of disposable equipment compared to ME and coblation. Implications for Practice: Surgeons desiring to reduce cost and waste associated with tonsillectomy surgery may consider transitioning to cold technique.