Cold pressure welding has been used to produce a lap junction between 0.15 mm thick strips of copper and constantan which had been plated with 2 mu m of nickel. The junction thickness after welding was 0.10 mm, and after further cold rolling to 0.06 mm a thermocouple performance within the requirements of BS 1041 (1966) was obtained.