Abstract

The first criticality of a new KZ-202 neutron moderator on the IBR-2M reactor is achieved. The moderator consists of thermal and cold units. The former is a room-temperature comb water moderator; the latter, a moderator using a mixture of aromatic hydrocarbons (mesitylene and m-xylene). The cold moderator is filled with granules of this mixture, which are supplied by a cold helium flow, and operates at 30 K. The combination of two units in one moderator makes it possible to simultaneously take the thermal and cold neutron spectra for extracted-beam spectrometers. The arrangement of the thermal and cold moderators is numerically optimized by the Monte Carlo method. The use of the cold moderator allows a 13-fold increase in the cold neutron intensity from its surface.